{"id":4346,"date":"2025-11-04T10:30:22","date_gmt":"2025-11-04T09:30:22","guid":{"rendered":"https:\/\/ghetool.eu\/?post_type=knowledgebase&#038;p=4346"},"modified":"2025-11-04T10:31:13","modified_gmt":"2025-11-04T09:31:13","slug":"como-evitar-el-desequilibrio","status":"publish","type":"knowledgebase","link":"https:\/\/ghetool.eu\/es_es\/knowledgebase\/how-to-avoid-imbalance\/","title":{"rendered":"\u00bfC\u00f3mo evitar el desequilibrio?"},"content":{"rendered":"<p>El desequilibrio es un aspecto central e importante en el mundo del dise\u00f1o geot\u00e9rmico. La semana pasada hablamos de c\u00f3mo afrontarlo a la hora de dise\u00f1ar el campo de sondeos, pero hoy daremos un paso atr\u00e1s y analizaremos distintas formas de evitarlo.<\/p>\n<p><iframe title=\"\u00bfC\u00f3mo evitar el desequilibrio?\" width=\"800\" height=\"450\" src=\"https:\/\/www.youtube.com\/embed\/BrwhCJNL6oY?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<h2>\u00bfQu\u00e9 es el desequilibrio?<\/h2>\n<p>El desequilibrio es el calentamiento o enfriamiento anual del suelo causado por una diferencia entre la energ\u00eda extra\u00edda y la inyectada anualmente. En ese sentido, est\u00e1 totalmente determinado por la demanda energ\u00e9tica de su edificio y es algo con lo que simplemente hay que aprender a lidiar. A continuaci\u00f3n, puede ver un ejemplo de un campo de sondeo dominado por la extracci\u00f3n.<\/p>\n<figure id=\"attachment_3614\" aria-describedby=\"caption-attachment-3614\" style=\"width: 1650px\" class=\"wp-caption aligncenter\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-3614 size-full\" src=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance.png\" alt=\"Representaci\u00f3n gr\u00e1fica del desequilibrio.\" width=\"1650\" height=\"1047\" srcset=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance.png 1650w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance-300x190.png 300w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance-1024x650.png 1024w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance-768x487.png 768w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance-1536x975.png 1536w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance-18x12.png 18w\" sizes=\"(max-width: 1650px) 100vw, 1650px\" \/><figcaption id=\"caption-attachment-3614\" class=\"wp-caption-text\">Representaci\u00f3n gr\u00e1fica del desequilibrio.<\/figcaption><\/figure>\n<p>La demanda geot\u00e9rmica anterior se traduce en el campo de perforaci\u00f3n dominado por la extracci\u00f3n que se muestra a continuaci\u00f3n. Como puede verse, la temperatura desciende a\u00f1o tras a\u00f1o porque se extrae m\u00e1s energ\u00eda de la que se inyecta. Esto ejerce una presi\u00f3n considerable sobre el umbral m\u00ednimo al final del periodo de simulaci\u00f3n, ya que se convierte en el punto cr\u00edtico de dise\u00f1o. Cuanto mayor sea el desequilibrio, m\u00e1s metros de perforaci\u00f3n (y, por tanto, m\u00e1s inversi\u00f3n) ser\u00e1n necesarios para hacerle frente.<\/p>\n<blockquote><p><span style=\"color: #3366ff;\"><strong>Nota<\/strong><\/span><br \/>\n<span style=\"color: #3366ff;\">No todos los desequilibrios conllevan por definici\u00f3n m\u00e1s metros de perforaci\u00f3n y, por tanto, mayores costes de inversi\u00f3n. Cuando existe un cierto desequilibrio pero su perforaci\u00f3n ya est\u00e1 limitada en el primer a\u00f1o debido a una potencia punta elevada, pierde importancia. Encontrar\u00e1 m\u00e1s informaci\u00f3n en <a style=\"text-decoration: underline; color: #3366ff;\" href=\"https:\/\/ghetool.eu\/es_es\/base-de-conocimientos\/cuadrantes-del-campo-de-perforacion\/\">nuestro art\u00edculo<\/a> en los cuadrantes del campo de perforaci\u00f3n.<\/span><\/p><\/blockquote>\n<figure id=\"attachment_3618\" aria-describedby=\"caption-attachment-3618\" style=\"width: 744px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"wp-image-3618 size-full\" src=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Quadrant-4.png\" alt=\"Borefield cuadrante 4\" width=\"744\" height=\"400\" srcset=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Quadrant-4.png 744w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Quadrant-4-300x161.png 300w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Quadrant-4-18x10.png 18w\" sizes=\"(max-width: 744px) 100vw, 744px\" \/><figcaption id=\"caption-attachment-3618\" class=\"wp-caption-text\">Ejemplo de un yacimiento limitado por la temperatura media m\u00ednima del fluido.<\/figcaption><\/figure>\n<div class=\"mceTemp\"><\/div>\n<h2>\u00bfEvitar o afrontar?<\/h2>\n<p>Est\u00e1 claro que el desequilibrio puede plantear retos considerables para el dise\u00f1o de su campo de perforaci\u00f3n y, como ocurre con la mayor\u00eda de los retos de la vida, puede intentar evitarlo o aprender a afrontarlo.<\/p>\n<p>La semana pasada estudiamos distintas formas de hacer frente al desequilibrio una vez que se hab\u00eda producido. (Puedes encontrar el art\u00edculo <a style=\"text-decoration: underline;\" href=\"https:\/\/ghetool.eu\/es_es\/base-de-conocimientos\/como-afrontar-el-desequilibrio\/\">aqu\u00ed<\/a>.) Esta semana daremos un paso atr\u00e1s y analizaremos las distintas opciones de dise\u00f1o disponibles para evitar el desequilibrio. Esto puede hacerse de dos maneras: teniendo en cuenta las decisiones arquitect\u00f3nicas del edificio o utilizando un enfoque m\u00e1s basado en el sistema. Ambas se explican a continuaci\u00f3n.<img decoding=\"async\" class=\"wp-image-4339 size-full\" src=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/10\/Avoid-or-cope-scaled.png\" alt=\"Representaci\u00f3n gr\u00e1fica del origen del desequilibrio y de d\u00f3nde se puede hacer frente a \u00e9l.\" width=\"2560\" height=\"502\" srcset=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/10\/Avoid-or-cope-scaled.png 2560w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/10\/Avoid-or-cope-300x59.png 300w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/10\/Avoid-or-cope-1024x201.png 1024w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/10\/Avoid-or-cope-768x151.png 768w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/10\/Avoid-or-cope-1536x301.png 1536w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/10\/Avoid-or-cope-2048x401.png 2048w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/10\/Avoid-or-cope-18x4.png 18w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><\/p>\n<p>Representaci\u00f3n gr\u00e1fica del origen del desequilibrio y de d\u00f3nde se puede hacer frente a \u00e9l.<\/p>\n<h2>Enfoque arquitect\u00f3nico<\/h2>\n<p>Como ya se ha dicho, el desequilibrio es consecuencia de la demanda de calefacci\u00f3n, refrigeraci\u00f3n y agua caliente sanitaria del edificio, pero esas demandas no est\u00e1n grabadas en piedra. Por supuesto, aspectos como la ocupaci\u00f3n y los niveles de confort son bastante estrictos e inmutables, pero en la fase de dise\u00f1o arquitect\u00f3nico de un proyecto podemos influir en varios factores que determinar\u00e1n la demanda final de calefacci\u00f3n y refrigeraci\u00f3n del edificio. A continuaci\u00f3n se exponen algunos de ellos.<\/p>\n<h3>Persianas solares<\/h3>\n<p>Una de las discusiones m\u00e1s habituales en la fase arquitect\u00f3nica de un proyecto es si instalar persianas solares para evitar que el edificio se sobrecaliente en verano.<\/p>\n<figure id=\"attachment_4348\" aria-describedby=\"caption-attachment-4348\" style=\"width: 400px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-4348 size-full\" src=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/11\/Solar-shades.jpg\" alt=\"Ejemplo de persianas solares. (Fuente: https:\/\/www.theshadestore.com\/blog\/buying-guides\/solar-shades-for-windows)\" width=\"400\" height=\"330\" srcset=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/11\/Solar-shades.jpg 400w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/11\/Solar-shades-300x248.jpg 300w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/11\/Solar-shades-15x12.jpg 15w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><figcaption id=\"caption-attachment-4348\" class=\"wp-caption-text\">Ejemplo de persianas solares. (Fuente: https:\/\/www.theshadestore.com\/blog\/buying-guides\/solar-shades-for-windows)<\/figcaption><\/figure>\n<p>Aunque esto puede ser una buena idea por razones de comodidad, la instalaci\u00f3n de protecci\u00f3n solar disminuir\u00e1 la demanda de refrigeraci\u00f3n del edificio, y cuando se tiene un campo de sondeo dominado por la extracci\u00f3n (donde la temperatura bajar\u00e1 a\u00f1o tras a\u00f1o), esto no es lo ideal. En ese caso, lo que se necesita es una mayor demanda de refrigeraci\u00f3n para equilibrar el campo de perforaci\u00f3n.<\/p>\n<blockquote><p><span style=\"color: #3366ff;\"><strong>Nota<br \/>\n<\/strong>En lugar de colocar persianas solares, ser\u00eda mejor explorar formas de mantener fresco el edificio sin reducir la propia demanda de refrigeraci\u00f3n, ya que eso afecta al desequilibrio. Por ejemplo, podr\u00eda utilizar ventiladores de refrigeraci\u00f3n para ayudar a hacer frente a la elevada demanda de refrigeraci\u00f3n en verano. Sin embargo, aseg\u00farate siempre de que tu campo de perforaci\u00f3n tambi\u00e9n pueda soportar los picos de demanda de refrigeraci\u00f3n.<\/span><\/p><\/blockquote>\n<h3>Windows<\/h3>\n<p data-start=\"90\" data-end=\"506\">Adem\u00e1s de las persianas solares, el tama\u00f1o y la ubicaci\u00f3n de las ventanas tambi\u00e9n influyen significativamente en el desequilibrio. En primer lugar, el tama\u00f1o de las ventanas tiene un doble efecto: aumenta las ganancias solares en verano (elevando la demanda de refrigeraci\u00f3n y, por tanto, la carga de inyecci\u00f3n en el campo de sondeos), pero, por otro lado, tambi\u00e9n aumenta las p\u00e9rdidas de calor por conducci\u00f3n en invierno (elevando la demanda de calefacci\u00f3n y, por tanto, la carga de extracci\u00f3n en el campo de sondeos).<\/p>\n<p data-start=\"513\" data-end=\"864\">La magnitud relativa de estos efectos viene determinada por la colocaci\u00f3n o ubicaci\u00f3n de las ventanas. Una ventana en la fachada norte del edificio s\u00f3lo aumentar\u00e1 ligeramente la carga de refrigeraci\u00f3n, mientras que una ventana en la fachada sur provocar\u00e1 un aumento considerable de la demanda de refrigeraci\u00f3n. Las p\u00e9rdidas de calor en invierno son menos sensibles a la orientaci\u00f3n.<\/p>\n<p data-start=\"871\" data-end=\"1180\">Adem\u00e1s del tama\u00f1o y la orientaci\u00f3n de las ventanas, sus valores U y g tambi\u00e9n marcan la diferencia. El primer par\u00e1metro afecta a la calidad de aislamiento de la ventana (y, por tanto, influye en la demanda de calefacci\u00f3n o extracci\u00f3n), mientras que el segundo afecta a las ganancias solares (que influyen en la demanda de refrigeraci\u00f3n o inyecci\u00f3n).<\/p>\n<h3>Material del suelo<\/h3>\n<p>Un \u00faltimo tema que influye significativamente en el desequilibrio geot\u00e9rmico es el material del suelo. Las dos situaciones que se describen a continuaci\u00f3n utilizan sistemas de calefacci\u00f3n por suelo radiante, pero una est\u00e1 acabada con baldosas de cer\u00e1mica, mientras que la otra tiene un suelo de madera maciza.<\/p>\n<figure id=\"attachment_4349\" aria-describedby=\"caption-attachment-4349\" style=\"width: 2560px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-4349 size-full\" src=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/11\/Floor-type-scaled.png\" alt=\"Dos materiales diferentes para calentar el suelo. (Fuente izquierda: https:\/\/www.ctm.com.na\/floors\/tile-styles\/large-format-floor-tiles\/cashmere-cement-grey-ecotec-shiny-glazed-porcelain-floor-tile-800-x-800mm-v2-product.html, derecha: https:\/\/www.ghsproducts.com\/viken-6-inch-hardened-wood-flooring-misty-white-oak\/?srsltid=AfmBOorKpeBCIULB0oqurQSQqIXlmgtNqdT9Fa-fI-UTRtyBx9hjFQRU)\" width=\"2560\" height=\"915\" srcset=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/11\/Floor-type-scaled.png 2560w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/11\/Floor-type-300x107.png 300w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/11\/Floor-type-1024x366.png 1024w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/11\/Floor-type-768x275.png 768w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/11\/Floor-type-1536x549.png 1536w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/11\/Floor-type-2048x732.png 2048w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/11\/Floor-type-18x6.png 18w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><figcaption id=\"caption-attachment-4349\" class=\"wp-caption-text\">Dos materiales diferentes para calentar el suelo. (Fuente izquierda: https:\/\/www.ctm.com.na\/floors\/tile-styles\/large-format-floor-tiles\/cashmere-cement-grey-ecotec-shiny-glazed-porcelain-floor-tile-800-x-800mm-v2-product.html, derecha: https:\/\/www.ghsproducts.com\/viken-6-inch-hardened-wood-flooring-misty-white-oak\/?srsltid=AfmBOorKpeBCIULB0oqurQSQqIXlmgtNqdT9Fa-fI-UTRtyBx9hjFQRU)<\/figcaption><\/figure>\n<p>Adem\u00e1s de la diferencia est\u00e9tica, el comportamiento t\u00e9rmico de ambos suelos es extremadamente diferente. El suelo cer\u00e1mico es muy buen conductor del calor, mientras que el de madera act\u00faa m\u00e1s como aislante. Esto significa que, si desea utilizar la refrigeraci\u00f3n del suelo, un suelo cer\u00e1mico funcionar\u00e1 casi un 50% mejor que uno de madera. Esto no s\u00f3lo afecta al confort t\u00e9rmico, sino tambi\u00e9n al desequilibrio, ya que un suelo de madera captar\u00e1 menos demanda de refrigeraci\u00f3n, lo que se traducir\u00e1 en una menor carga de inyecci\u00f3n en el campo de perforaci\u00f3n.<\/p>\n<h2>Enfoque sist\u00e9mico<\/h2>\n<p>Las opciones comentadas anteriormente pueden utilizarse para modificar la demanda del edificio hasta cierto punto, pero antes de abordar el desequilibrio en nuestro dise\u00f1o geot\u00e9rmico, hay otro enfoque que podemos adoptar para evitarlo: el enfoque de sistema. A continuaci\u00f3n se analizan ambas opciones, la hibridaci\u00f3n y la regeneraci\u00f3n.<\/p>\n<h3>Hibridaci\u00f3n<\/h3>\n<p>Dise\u00f1amos un sistema de calefacci\u00f3n, ventilaci\u00f3n y aire acondicionado para proporcionar al edificio la calefacci\u00f3n y la refrigeraci\u00f3n necesarias, pero, dependiendo de la configuraci\u00f3n, s\u00f3lo una parte de esta demanda es satisfecha por el campo de sondeos. Cuando volvemos a ver el gr\u00e1fico del desequilibrio, queda claro que el edificio tiene una demanda de calefacci\u00f3n mayor que la de refrigeraci\u00f3n (como se ve por una extracci\u00f3n mayor que la inyecci\u00f3n de calor), lo que provoca el desequilibrio.<\/p>\n<figure id=\"attachment_3614-2\" aria-describedby=\"caption-attachment-3614-2\" style=\"width: 1650px\" class=\"wp-caption alignnone\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-3614 size-full\" src=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance.png\" alt=\"Representaci\u00f3n gr\u00e1fica del desequilibrio.\" width=\"1650\" height=\"1047\" srcset=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance.png 1650w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance-300x190.png 300w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance-1024x650.png 1024w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance-768x487.png 768w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance-1536x975.png 1536w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance-18x12.png 18w\" sizes=\"(max-width: 1650px) 100vw, 1650px\" \/><figcaption id=\"caption-attachment-3614-2\" class=\"wp-caption-text\">Representaci\u00f3n gr\u00e1fica del desequilibrio.<\/figcaption><\/figure>\n<p data-start=\"90\" data-end=\"450\">Un enfoque para equilibrar el campo de perforaci\u00f3n consiste en retirar parte de la demanda de calefacci\u00f3n del edificio del sistema geot\u00e9rmico y asignarla a otra tecnolog\u00eda, como una bomba de calor aire-agua, una caldera de gas o un calentador el\u00e9ctrico. De este modo, no alteramos la demanda del edificio en s\u00ed, sino que eliminamos el desequilibrio geot\u00e9rmico desplazando parte de la carga a otro lugar.<\/p>\n<blockquote><p><span style=\"color: #3366ff;\"><strong>Nota<\/strong><\/span><br \/>\n<span style=\"color: #3366ff;\">Como se menciona en <a style=\"text-decoration: underline; color: #3366ff;\" href=\"https:\/\/ghetool.eu\/es_es\/base-de-conocimientos\/cuadrantes-del-campo-de-perforacion\/\">nuestro art\u00edculo<\/a> en los cuadrantes del campo de sondeos, las cargas de inyecci\u00f3n y extracci\u00f3n no son id\u00e9nticas a las demandas de refrigeraci\u00f3n y calefacci\u00f3n del edificio, ya que entre ellas funciona una bomba de calor. Adem\u00e1s, si tambi\u00e9n se produce agua caliente sanitaria con la bomba de calor geot\u00e9rmica, parte de la carga de extracci\u00f3n procede de ella. Sin embargo, a efectos de este art\u00edculo, nos abstendremos de ello.<\/span><\/p><\/blockquote>\n<p><strong>Ejemplo de sistema h\u00edbrido<\/strong><\/p>\n<p>Aunque los sistemas h\u00edbridos (como analizamos ampliamente en <a style=\"text-decoration: underline;\" href=\"https:\/\/ghetool.eu\/es_es\/base-de-conocimientos\/?e-filter-e74df27-knowledgebase-category=hybrid-systems\">nuestros art\u00edculos sobre el tema<\/a>) suelen utilizarse en instalaciones de mayor tama\u00f1o, tambi\u00e9n pueden aparecer en proyectos residenciales m\u00e1s peque\u00f1os. Un ejemplo es un edificio con calefacci\u00f3n y refrigeraci\u00f3n por suelo radiante acopladas a una bomba de calor geot\u00e9rmica, que se calienta demasiado en verano. Para evitar el sobrecalentamiento, los propietarios instalan una unidad split de aire acondicionado independiente para satisfacer la demanda de refrigeraci\u00f3n. Entonces tenemos un sistema h\u00edbrido en el que hay una bomba de calor geot\u00e9rmica y otra de aire.<\/p>\n<p data-start=\"603\" data-end=\"997\">Sin embargo, si el sistema geot\u00e9rmico est\u00e1 dominado por la extracci\u00f3n, el sistema h\u00edbrido descrito anteriormente no ser\u00e1 beneficioso para el desequilibrio. La unidad dividida puede enfriar f\u00e1cilmente la temperatura ambiente a 21 \u00b0C, sin dejar carga de refrigeraci\u00f3n para el sistema de refrigeraci\u00f3n del suelo. Como resultado, la cantidad de calor inyectada de nuevo en el campo de sondeo ser\u00e1 casi nula, lo que podr\u00eda provocar un aumento significativo del desequilibrio.<\/p>\n<p data-start=\"1004\" data-end=\"1221\">Por otra parte, si la unidad dividida se utiliza tambi\u00e9n para ayudar a calentar en invierno, puede quitar parte de la demanda de calefacci\u00f3n del edificio al campo de sondeo, lo que ser\u00eda beneficioso para el equilibrio de \u00e9ste.<\/p>\n<h3>Regeneraci\u00f3n<\/h3>\n<p>Otro m\u00e9todo para reducir el desequilibrio en el campo de perforaci\u00f3n es la regeneraci\u00f3n. En este caso, en lugar de retirar parte de la carga del campo de sondeo para compensar el desequilibrio, aumentamos la carga opuesta. Por ejemplo, en el caso siguiente, en el que la extracci\u00f3n es mayor que la inyecci\u00f3n, podemos aumentar la demanda de inyecci\u00f3n instalando refrigeradores secos, absorbedores solares o sistemas similares. De este modo, se compensa de nuevo el desequilibrio.<\/p>\n<blockquote>\n<figure id=\"attachment_3614-3\" aria-describedby=\"caption-attachment-3614-3\" style=\"width: 1650px\" class=\"wp-caption alignnone\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-3614 size-full\" src=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance.png\" alt=\"Representaci\u00f3n gr\u00e1fica del desequilibrio.\" width=\"1650\" height=\"1047\" srcset=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance.png 1650w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance-300x190.png 300w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance-1024x650.png 1024w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance-768x487.png 768w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance-1536x975.png 1536w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/01\/Ground-balance-18x12.png 18w\" sizes=\"(max-width: 1650px) 100vw, 1650px\" \/><figcaption id=\"caption-attachment-3614-3\" class=\"wp-caption-text\">Representaci\u00f3n gr\u00e1fica del desequilibrio.<\/figcaption><\/figure>\n<p><span style=\"color: #ff9900;\"><strong>Atenci\u00f3n<\/strong><\/span><br \/>\n<span style=\"color: #ff9900;\">Al regenerar el campo de sondeo, aumenta la carga que soporta. Es importante simular si el campo de sondeo puede soportar esta carga adicional. Por ejemplo, en el caso anterior, si se instalaran absorbedores solares para inyectar calor adicional en el suelo, aumentar\u00eda la potencia de inyecci\u00f3n y, por tanto, tambi\u00e9n la temperatura media del fluido en el interior del pozo. Debe asegurarse de que puede seguir suministrando la refrigeraci\u00f3n necesaria al edificio; en otras palabras, debe asegurarse de que la regeneraci\u00f3n no interfiere con el confort real del edificio.<\/span><\/p>\n<p><span style=\"color: #339966;\"><strong>Pr\u00f3ximamente<\/strong><\/span><br \/>\n<span style=\"color: #339966;\">El a\u00f1o que viene lanzaremos m\u00f3dulos para la regeneraci\u00f3n (junto a la hibridaci\u00f3n) en GHEtool Cloud. Est\u00e9 atento.<\/span><\/p><\/blockquote>\n<h2>Conclusi\u00f3n<\/h2>\n<p data-start=\"92\" data-end=\"397\">El desequilibrio desempe\u00f1a un papel importante en el trabajo de un dise\u00f1ador geot\u00e9rmico y, aunque se puede intentar solucionarlo durante la fase de dise\u00f1o de la perforaci\u00f3n, es mejor evitarlo por completo. En este art\u00edculo, nos centramos en dos enfoques para lograrlo: el enfoque arquitect\u00f3nico y el enfoque de sistema.<\/p>\n<p data-start=\"404\" data-end=\"902\">El primero puso de relieve la importancia de las opciones de dise\u00f1o del edificio relacionadas con el tama\u00f1o y la colocaci\u00f3n de las ventanas, la protecci\u00f3n solar y tambi\u00e9n el impacto del tipo de suelo cuando se trabaja con calefacci\u00f3n y refrigeraci\u00f3n por suelo radiante. La segunda introdujo la adici\u00f3n de otra tecnolog\u00eda al sistema de calefacci\u00f3n, ventilaci\u00f3n y aire acondicionado para crear un sistema h\u00edbrido, que retira parte de la carga del campo de sondeo para mantenerlo equilibrado, o un campo de sondeo regenerado, en el que contrarrestamos el desequilibrio inyectando o extrayendo calor adicional en \u00e9l o de \u00e9l.<\/p>\n<h2 id=\"reference\">Referencias<\/h2>\n<ul>\n<li>Vea nuestro v\u00eddeo explicativo en nuestra p\u00e1gina de YouTube haciendo clic en <span style=\"text-decoration: underline;\"><a href=\"https:\/\/youtu.be\/BrwhCJNL6oY\" target=\"_blank\" rel=\"noopener\">aqu\u00ed<\/a><\/span>.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>En casi todos los dise\u00f1os geot\u00e9rmicos, se encontrar\u00e1 con desequilibrios. A veces no es un problema grave, pero en otros casos supone un reto importante para mantener su campo de sondeo asequible y robusto a largo plazo. En este art\u00edculo, analizaremos c\u00f3mo puede gestionar el desequilibrio al dise\u00f1ar su pr\u00f3ximo campo de perforaci\u00f3n.<\/p>","protected":false},"template":"","pdf-article":[105],"authors":[39],"knowledgebase-category":[67,31],"class_list":["post-4346","knowledgebase","type-knowledgebase","status-publish","hentry","pdf-article-avoid-imbalance","authors-wouter-peere","knowledgebase-category-physics","knowledgebase-category-faq"],"_links":{"self":[{"href":"https:\/\/ghetool.eu\/es_es\/wp-json\/wp\/v2\/knowledgebase\/4346","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ghetool.eu\/es_es\/wp-json\/wp\/v2\/knowledgebase"}],"about":[{"href":"https:\/\/ghetool.eu\/es_es\/wp-json\/wp\/v2\/types\/knowledgebase"}],"wp:attachment":[{"href":"https:\/\/ghetool.eu\/es_es\/wp-json\/wp\/v2\/media?parent=4346"}],"wp:term":[{"taxonomy":"pdf-article","embeddable":true,"href":"https:\/\/ghetool.eu\/es_es\/wp-json\/wp\/v2\/pdf-article?post=4346"},{"taxonomy":"authors","embeddable":true,"href":"https:\/\/ghetool.eu\/es_es\/wp-json\/wp\/v2\/authors?post=4346"},{"taxonomy":"knowledgebase-category","embeddable":true,"href":"https:\/\/ghetool.eu\/es_es\/wp-json\/wp\/v2\/knowledgebase-category?post=4346"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}