{"id":4130,"date":"2025-07-08T06:26:18","date_gmt":"2025-07-08T04:26:18","guid":{"rendered":"https:\/\/ghetool.eu\/?post_type=knowledgebase&#038;p=4130"},"modified":"2025-07-10T06:24:46","modified_gmt":"2025-07-10T04:24:46","slug":"la-simulation-de-systemes-hybrides","status":"publish","type":"knowledgebase","link":"https:\/\/ghetool.eu\/fr_fr\/base-de-connaissances\/la-simulation-de-systemes-hybrides\/","title":{"rendered":"Simulation de syst\u00e8mes hybrides avec GHEtool"},"content":{"rendered":"<p>Jusqu'\u00e0 pr\u00e9sent, GHEtool offrait la possibilit\u00e9 d'optimiser les syst\u00e8mes hybrides, mais aujourd'hui nous introduisons un tout nouveau module de simulation. La simulation et l'optimisation \u00e9tant d\u00e9sormais disponibles, vous disposez d'une bo\u00eete \u00e0 outils compl\u00e8te pour concevoir des syst\u00e8mes g\u00e9othermiques hybrides plus performants et plus efficaces.<\/p>\n<p><iframe title=\"Simulation de syst\u00e8mes hybrides\" width=\"800\" height=\"450\" src=\"https:\/\/www.youtube.com\/embed\/IYHfqGqV1p4?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<h2>Ce qu'il faut savoir sur les syst\u00e8mes hybrides<\/h2>\n<p>Nous avons d\u00e9j\u00e0 \u00e9crit plusieurs articles sur l'optimisation des syst\u00e8mes hybrides. En <a style=\"text-decoration: underline;\" href=\"https:\/\/ghetool.eu\/fr_fr\/base-de-connaissances\/systemes-hybrides-et-potentiel-geothermique\/\">un premier article<\/a>, Nous avons pr\u00e9sent\u00e9 le concept de syst\u00e8mes hybrides et le potentiel g\u00e9othermique. Les syst\u00e8mes hybrides ont \u00e9t\u00e9 d\u00e9finis comme la combinaison de diff\u00e9rentes technologies de chauffage et de refroidissement qui, ensemble, r\u00e9pondent \u00e0 la demande thermique du b\u00e2timent. Il peut s'agir d'une pompe \u00e0 chaleur g\u00e9othermique (PCS) combin\u00e9e \u00e0 une pompe \u00e0 chaleur \u00e0 air (PACA), d'un refroidisseur sec avec une PCS, etc.<\/p>\n<p>Le dimensionnement d'un syst\u00e8me hybride n'est pas trivial, et encore moins celui d'un syst\u00e8me g\u00e9othermique hybride. C'est pourquoi, dans <a style=\"text-decoration: underline;\" href=\"https:\/\/ghetool.eu\/fr_fr\/base-de-connaissances\/systemes-hybrides-et-methodologie-de-conception\/\">un deuxi\u00e8me article<\/a>, Pour y parvenir, nous avons introduit deux m\u00e9thodologies de conception : l'optimisation de la puissance et l'optimisation de l'\u00e9nergie. La premi\u00e8re approche aboutit \u00e0 un syst\u00e8me dont le co\u00fbt d'investissement est le plus faible (en raison du surdimensionnement de 0%), mais une partie du potentiel g\u00e9othermique reste inutilis\u00e9e. Si, au contraire, vous optimisez le syst\u00e8me pour un \u00e9change d'\u00e9nergie maximal, vous surdimensionnez d\u00e9lib\u00e9r\u00e9ment la pompe \u00e0 chaleur pour \u00e9changer plus d'\u00e9nergie avec le sol, ce qui r\u00e9duit les co\u00fbts d'exploitation. Un exemple de cette m\u00e9thode a \u00e9t\u00e9 pr\u00e9sent\u00e9 dans <a style=\"text-decoration: underline;\" href=\"https:\/\/ghetool.eu\/fr_fr\/base-de-connaissances\/systemes-hybrides-et-ghetool-cloud\/\">un troisi\u00e8me article<\/a>.<\/p>\n<p>Une autre innovation a \u00e9t\u00e9 apport\u00e9e par l'introduction d'une approche plus g\u00e9n\u00e9ralis\u00e9e : l'optimisation de l'\u00e9quilibre, comme nous l'avons expliqu\u00e9 dans notre article sur le th\u00e8me de l'\u00e9quilibre. <a style=\"text-decoration: underline;\" href=\"https:\/\/ghetool.eu\/fr_fr\/base-de-connaissances\/les-systemes-hybrides-optimisent-lequilibre\/\">quatri\u00e8me article<\/a>. Ici, vous pouvez vous assurer que la r\u00e9partition entre l'\u00e9nergie g\u00e9othermique et les syst\u00e8mes auxiliaires se fait de mani\u00e8re \u00e0 ne laisser subsister qu'un certain d\u00e9s\u00e9quilibre contr\u00f4l\u00e9.<\/p>\n<p>Ensemble, ces trois m\u00e9thodologies constituent une bo\u00eete \u00e0 outils puissante pour trouver des solutions optimales. Cependant, il leur manque encore un \u00e9l\u00e9ment cl\u00e9 : la flexibilit\u00e9 n\u00e9cessaire pour mettre en \u0153uvre votre propre strat\u00e9gie de contr\u00f4le.<\/p>\n<h2>Simulation de syst\u00e8mes hybrides<\/h2>\n<h3>La diff\u00e9rence entre l'optimisation et la simulation<\/h3>\n<p>Toutes les m\u00e9thodes actuellement disponibles dans GHEtool Cloud sont des m\u00e9thodes d'optimisation. Cela signifie que, compte tenu de certaines conditions limites, telles qu'une taille fixe de champ de forage et une demande thermique horaire, vous maximisez la part g\u00e9othermique en optimisant la puissance, l'\u00e9nergie ou l'\u00e9quilibre. Ce processus peut \u00eatre quelque peu lent, car il peut n\u00e9cessiter de nombreuses it\u00e9rations, et c'est pr\u00e9cis\u00e9ment l\u00e0 que la flexibilit\u00e9 de la simulation entre en jeu.<\/p>\n<p>Lorsque vous simulez un syst\u00e8me hybride, vous partez toujours des m\u00eames conditions connues (la taille de votre champ de forage et la demande thermique horaire), mais vous d\u00e9finissez \u00e9galement la strat\u00e9gie de contr\u00f4le de votre syst\u00e8me hybride. En d'autres termes, \u00e0 partir de quelle temp\u00e9rature seuil une technologie donn\u00e9e doit-elle \u00eatre activ\u00e9e ou d\u00e9sactiv\u00e9e ? Avec cette strat\u00e9gie et un fichier m\u00e9t\u00e9orologique donn\u00e9, la demande g\u00e9othermique peut \u00eatre calcul\u00e9e directement sur la base de la logique de contr\u00f4le, sans qu'il soit n\u00e9cessaire de proc\u00e9der \u00e0 des it\u00e9rations. Les simulations sont donc beaucoup plus rapides. Cependant, la contrepartie est que vous ne travaillez pas n\u00e9cessairement avec la solution optimale.<\/p>\n<blockquote><p><span style=\"color: #3366ff;\"><strong>!Note<\/strong><strong><br \/>\n<\/strong>Si vous utilisez les m\u00e9thodes d'optimisation, une strat\u00e9gie de contr\u00f4le est impliqu\u00e9e. Puisque vous souhaitez que les temp\u00e9ratures de vos fluides restent dans certaines limites, l'algorithme d'optimisation adaptera la charge en cons\u00e9quence pour r\u00e9pondre \u00e0 cette exigence. Bien que cette strat\u00e9gie de contr\u00f4le puisse \u00eatre reproduite dans la r\u00e9alit\u00e9 en utilisant un point de consigne de contr\u00f4leur bas\u00e9 sur la temp\u00e9rature des fluides g\u00e9othermiques, il n'est pas facile de le faire.<br \/>\n<\/span><\/p><\/blockquote>\n<h3>Trois exemples de simulation de syst\u00e8mes hybrides<\/h3>\n<p>Imaginons que vous ayez un grand b\u00e2timent commercial dont une partie de la charge est assur\u00e9e par une GSHP et l'autre par une ASHP. Comme vous savez que lorsque la temp\u00e9rature de l'air ext\u00e9rieur est sup\u00e9rieure \u00e0 10 \u00b0C, votre pompe \u00e0 chaleur automatique a un meilleur rendement que votre pompe \u00e0 chaleur g\u00e9n\u00e9rale, il est logique, du point de vue de la consommation d'\u00e9lectricit\u00e9, d'utiliser de pr\u00e9f\u00e9rence la pompe \u00e0 chaleur automatique au lieu de la pompe \u00e0 chaleur g\u00e9n\u00e9rale. Ceci peut \u00eatre facilement mod\u00e9lis\u00e9 en d\u00e9finissant l'ASHP comme une <em>une technologie de chauffage hybride qui fonctionne \u00e0 partir d'une temp\u00e9rature seuil<\/em>.<\/p>\n<p>Une autre situation peut se produire, par exemple, dans le cadre d'une r\u00e9novation. Imaginez que vous ayez un b\u00e2timent scolaire (pas tr\u00e8s bien isol\u00e9) avec des syst\u00e8mes d'\u00e9mission \u00e0 haute temp\u00e9rature aliment\u00e9s par une chaudi\u00e8re \u00e0 gaz. En automne et au printemps, la GSHP peut parfaitement chauffer ce b\u00e2timent, mais lorsqu'il fait trop froid \u00e0 l'ext\u00e9rieur, la chaudi\u00e8re \u00e0 gaz se met en marche pour fournir les temp\u00e9ratures plus \u00e9lev\u00e9es requises. Ce ph\u00e9nom\u00e8ne peut \u00eatre mod\u00e9lis\u00e9 \u00e0 l'aide d'un <em>syst\u00e8me de chauffage hybride fonctionnant en dessous d'un seuil de temp\u00e9rature<\/em>.<\/p>\n<p>Un dernier exemple pourrait \u00eatre celui d'un immeuble de bureaux, o\u00f9 la centrale de traitement de l'air (CTA) a des difficult\u00e9s \u00e0 refroidir l'air en utilisant les temp\u00e9ratures passives du champ de forage lorsqu'il fait trop chaud \u00e0 l'ext\u00e9rieur. Une solution pourrait consister \u00e0 \u00e9quiper la CTA d'un composant actif qui se met en marche pour fournir de l'air frais. <em>le refroidissement hybride \u00e0 partir d'un certain seuil de temp\u00e9rature<\/em>.<\/p>\n<blockquote><p><span style=\"color: #3366ff;\"><strong>!Note<\/strong><\/span><br \/>\n<span style=\"color: #3366ff;\">Il existe \u00e9galement une quatri\u00e8me option, dans laquelle un syst\u00e8me hybride assure le refroidissement lorsque la temp\u00e9rature de l'air ext\u00e9rieur descend en dessous d'un certain niveau. Il peut s'agir, par exemple, du refroidissement de la ventilation nocturne. Comme il ne s'agit pas vraiment d'un \u2018syst\u00e8me\u2019, cette option - bien que pr\u00e9sente dans GHEtool - ne sera pas examin\u00e9e plus avant.<\/span><\/p><\/blockquote>\n<p>Dans ce qui suit, nous verrons comment vous pouvez utiliser GHEtool Cloud pour simuler ces syst\u00e8mes.<\/p>\n<h2>Simulation de syst\u00e8mes hybrides avec GHEtool Cloud<\/h2>\n<p>Dans GHEtool, vous avez d\u00e9sormais la possibilit\u00e9 (lorsque vous avez t\u00e9l\u00e9charg\u00e9 un profil de charge horaire) d'ajouter un syst\u00e8me hybride lors du calcul du profil de temp\u00e9rature. Une capture d'\u00e9cran de la section d'entr\u00e9e est pr\u00e9sent\u00e9e ci-dessous.<\/p>\n<blockquote><p><span style=\"color: #0000ff;\"><strong>!Note<\/strong><\/span><br \/>\n<span style=\"color: #0000ff;\">Comme la simulation n'est pas un processus it\u00e9ratif, il est \u00e9galement possible d'ajouter un syst\u00e8me hybride lors du calcul de la profondeur de forage requise.<\/span><\/p><\/blockquote>\n<figure id=\"attachment_4133\" aria-describedby=\"caption-attachment-4133\" style=\"width: 1598px\" class=\"wp-caption aligncenter\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-4133 size-full\" src=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Hybrid-system-in-GHEtool-Cloud.png\" alt=\"\u00c9cran d&#039;impression du module des syst\u00e8mes hybrides dans GHEtool Cloud.\" width=\"1598\" height=\"447\" srcset=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Hybrid-system-in-GHEtool-Cloud.png 1598w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Hybrid-system-in-GHEtool-Cloud-300x84.png 300w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Hybrid-system-in-GHEtool-Cloud-1024x286.png 1024w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Hybrid-system-in-GHEtool-Cloud-768x215.png 768w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Hybrid-system-in-GHEtool-Cloud-1536x430.png 1536w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Hybrid-system-in-GHEtool-Cloud-18x5.png 18w\" sizes=\"(max-width: 1598px) 100vw, 1598px\" \/><figcaption id=\"caption-attachment-4133\" class=\"wp-caption-text\">\u00c9cran d'impression du module des syst\u00e8mes hybrides dans GHEtool Cloud.<\/figcaption><\/figure>\n<p>Tout d'abord, puisque ces simulations de syst\u00e8mes hybrides sont toutes bas\u00e9es sur un seuil de temp\u00e9rature ext\u00e9rieure, un fichier m\u00e9t\u00e9orologique EPW est n\u00e9cessaire. Id\u00e9alement, le m\u00eame fichier m\u00e9t\u00e9o utilis\u00e9 pour le calcul de la charge horaire est \u00e9galement utilis\u00e9 pour la simulation, de sorte que les demandes thermiques de pointe co\u00efncident avec les informations m\u00e9t\u00e9orologiques correctes.<\/p>\n<blockquote><p><span style=\"color: #0000ff;\"><strong>!Note<\/strong><\/span><br \/>\n<span style=\"color: #0000ff;\">Lors de la recherche de fichiers m\u00e9t\u00e9orologiques, <a style=\"color: #0000ff;\" href=\"https:\/\/climate.onebuilding.org\/\" target=\"_blank\" rel=\"noopener\">https:\/\/climate.onebuilding.org\/<\/a> fournit gratuitement des fichiers EPW pour presque toutes les r\u00e9gions du monde et pour diff\u00e9rentes ann\u00e9es.<\/span><\/p><\/blockquote>\n<p>Ensuite, vous avez la possibilit\u00e9 d'ajouter jusqu'\u00e0 quatre syst\u00e8mes hybrides diff\u00e9rents, chacun ayant son propre seuil de temp\u00e9rature au-dessus ou au-dessous duquel le syst\u00e8me hybride respectif sera pr\u00e9f\u00e9r\u00e9 pour le chauffage ou le refroidissement. Pour chaque option de chauffage\/refroidissement hybride, vous pouvez \u00e9galement sp\u00e9cifier la puissance de ce syst\u00e8me hybride.<\/p>\n<blockquote><p><span style=\"color: #0000ff;\"><strong>Remarque !<br \/>\n<\/strong>Bien qu'il y ait quatre entr\u00e9es distinctes pour les syst\u00e8mes hybrides, cela ne signifie pas n\u00e9cessairement que quatre syst\u00e8mes diff\u00e9rents doivent \u00eatre mod\u00e9lis\u00e9s. Il est parfaitement possible de mod\u00e9liser une seule pompe \u00e0 chaleur qui assure \u00e0 la fois le chauffage et le refroidissement \u00e0 partir d'un certain seuil.<\/span><\/p><\/blockquote>\n<h3>Exemple de chauffage hybride<\/h3>\n<p>Le graphique ci-dessous montre la distribution de l'\u00e9nergie dans le cas d'un syst\u00e8me de chauffage hybride qui fournit 100 kW de chauffage lorsque la temp\u00e9rature ext\u00e9rieure descend en dessous de 2 \u00b0C. Comme le montre la figure, ce ph\u00e9nom\u00e8ne ne se produit (pour ce fichier m\u00e9t\u00e9orologique) qu'en janvier, f\u00e9vrier et d\u00e9cembre. Pour les autres mois, l'effet est n\u00e9gligeable.<\/p>\n<figure id=\"attachment_4135\" aria-describedby=\"caption-attachment-4135\" style=\"width: 1434px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"wp-image-4135 size-full\" src=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Heating-below-threshold.png\" alt=\"Simulation d&#039;un syst\u00e8me hybride avec 100 kW de puissance de chauffage en dessous de 2\u00b0C.\" width=\"1434\" height=\"600\" srcset=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Heating-below-threshold.png 1434w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Heating-below-threshold-300x126.png 300w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Heating-below-threshold-1024x428.png 1024w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Heating-below-threshold-768x321.png 768w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Heating-below-threshold-18x8.png 18w\" sizes=\"(max-width: 1434px) 100vw, 1434px\" \/><figcaption id=\"caption-attachment-4135\" class=\"wp-caption-text\">Simulation d'un syst\u00e8me hybride avec 100 kW de puissance de chauffage en dessous de 2\u00b0C.<\/figcaption><\/figure>\n<p>Lorsqu'un autre syst\u00e8me hybride est ajout\u00e9, fournissant 200 kW et fonctionnant lorsque la temp\u00e9rature ext\u00e9rieure est sup\u00e9rieure \u00e0 10 \u00b0C, le profil ressemble \u00e0 celui ci-dessous. Ici, vous pouvez voir que la part du chauffage g\u00e9othermique est nettement plus faible, ce qui entra\u00eene un d\u00e9s\u00e9quilibre diff\u00e9rent et, par cons\u00e9quent, un profil de temp\u00e9rature diff\u00e9rent.<\/p>\n<figure id=\"attachment_4136\" aria-describedby=\"caption-attachment-4136\" style=\"width: 1434px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\"wp-image-4136 size-full\" src=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Heating-above-and-below-threshold.png\" alt=\"Simulation d&#039;un syst\u00e8me hybride avec 100 kW de puissance de chauffage en dessous de 2\u00b0C et 200 kW au-dessus de 10\u00b0C.\" width=\"1434\" height=\"600\" srcset=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Heating-above-and-below-threshold.png 1434w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Heating-above-and-below-threshold-300x126.png 300w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Heating-above-and-below-threshold-1024x428.png 1024w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Heating-above-and-below-threshold-768x321.png 768w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Heating-above-and-below-threshold-18x8.png 18w\" sizes=\"(max-width: 1434px) 100vw, 1434px\" \/><figcaption id=\"caption-attachment-4136\" class=\"wp-caption-text\">Simulation d'un syst\u00e8me hybride avec 100 kW de puissance de chauffage en dessous de 2\u00b0C et 200 kW au-dessus de 10\u00b0C.<\/figcaption><\/figure>\n<h3>Limiter la puissance du champ de forage<\/h3>\n<p>Enfin, il est \u00e9galement possible de limiter la puissance g\u00e9othermique maximale. Imaginez, par exemple, que vous ayez une demande de chauffage de 536 kW et qu'une pompe \u00e0 chaleur soit d\u00e9j\u00e0 install\u00e9e pour fournir un rafra\u00eechissement suppl\u00e9mentaire en \u00e9t\u00e9. Vous pourriez alors limiter la puissance de pointe de la pompe \u00e0 chaleur g\u00e9othermique \u00e0 475 kW, par exemple. Cela signifie que dans vos r\u00e9sultats, il y aura d\u00e9sormais un \u2018exc\u00e8s de chauffage\u2019, puisque 100% de la charge de chauffage n'a pas pu \u00eatre satisfaite par la GSHP.<\/p>\n<p>En r\u00e9alit\u00e9, votre pompe \u00e0 chaleur peut prendre en charge cette partie de la charge, ce qui vous donne un autre moyen de concevoir et de simuler des syst\u00e8mes hybrides. Un exemple est pr\u00e9sent\u00e9 ci-dessous, o\u00f9 environ 1,3% de la demande annuelle de chauffage est maintenant indiqu\u00e9e comme \u2018chauffage exc\u00e9dentaire\u2019.<\/p>\n<figure id=\"attachment_4137\" aria-describedby=\"caption-attachment-4137\" style=\"width: 1434px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-4137 size-full\" src=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Borefield-1.png\" alt=\"Exemple de simulation hybride avec chauffage excessif.\" width=\"1434\" height=\"600\" srcset=\"https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Borefield-1.png 1434w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Borefield-1-300x126.png 300w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Borefield-1-1024x428.png 1024w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Borefield-1-768x321.png 768w, https:\/\/ghetool.eu\/wp-content\/uploads\/2025\/07\/Borefield-1-18x8.png 18w\" sizes=\"(max-width: 1434px) 100vw, 1434px\" \/><figcaption id=\"caption-attachment-4137\" class=\"wp-caption-text\">Exemple de simulation hybride avec chauffage excessif.<\/figcaption><\/figure>\n<h2>Conclusion<\/h2>\n<p>Le nouveau module de simulation des syst\u00e8mes hybrides compl\u00e8te parfaitement les m\u00e9thodes d'optimisation d\u00e9j\u00e0 disponibles. Bien qu'il ne garantisse pas la meilleure solution, il permet de simuler tr\u00e8s simplement le comportement des syst\u00e8mes hybrides dans la r\u00e9alit\u00e9.<\/p>\n<h2 id=\"reference\">R\u00e9f\u00e9rences<\/h2>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>Regardez notre vid\u00e9o d'explication sur notre page YouTube en cliquant sur <a style=\"text-decoration: underline;\" href=\"https:\/\/youtu.be\/IYHfqGqV1p4\" target=\"_blank\" rel=\"noopener\">ici<\/a>.<\/li>\n<\/ul>\n<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Jusqu'\u00e0 pr\u00e9sent, GHEtool offrait la possibilit\u00e9 d'optimiser les syst\u00e8mes hybrides, mais aujourd'hui nous introduisons un tout nouveau module de simulation. La simulation et l'optimisation \u00e9tant d\u00e9sormais disponibles, vous disposez d'une bo\u00eete \u00e0 outils compl\u00e8te pour concevoir des syst\u00e8mes g\u00e9othermiques hybrides plus performants et plus efficaces.<\/p>","protected":false},"template":"","pdf-article":[87],"authors":[39],"knowledgebase-category":[86,30],"class_list":["post-4130","knowledgebase","type-knowledgebase","status-publish","hentry","pdf-article-simulating-hybrid-systems","authors-wouter-peere","knowledgebase-category-hybrid-systems","knowledgebase-category-tutorial"],"_links":{"self":[{"href":"https:\/\/ghetool.eu\/fr_fr\/wp-json\/wp\/v2\/knowledgebase\/4130","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ghetool.eu\/fr_fr\/wp-json\/wp\/v2\/knowledgebase"}],"about":[{"href":"https:\/\/ghetool.eu\/fr_fr\/wp-json\/wp\/v2\/types\/knowledgebase"}],"wp:attachment":[{"href":"https:\/\/ghetool.eu\/fr_fr\/wp-json\/wp\/v2\/media?parent=4130"}],"wp:term":[{"taxonomy":"pdf-article","embeddable":true,"href":"https:\/\/ghetool.eu\/fr_fr\/wp-json\/wp\/v2\/pdf-article?post=4130"},{"taxonomy":"authors","embeddable":true,"href":"https:\/\/ghetool.eu\/fr_fr\/wp-json\/wp\/v2\/authors?post=4130"},{"taxonomy":"knowledgebase-category","embeddable":true,"href":"https:\/\/ghetool.eu\/fr_fr\/wp-json\/wp\/v2\/knowledgebase-category?post=4130"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}